Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application
PLANET ICS-2100T Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There is one 10/100BASE-TX RJ45 port in the ICS-2100T and its operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-2100T is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.
Remote Management
As the ICS-2100T provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for a large networking environment as well.
Stable Performance under Difficult Environments
The ICS-2100T provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-2100T to be placed in almost any difficult environment.
The ICS-2100T, equipped with compact IP30 standard metal case, allows either DIN-rail or wall mounting for efficient use of cabinet space. The ICS-2100T also provides an integrated power supply source with a wide range of voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.
Dual Power Input for High Availability Network System
The ICS-2100T features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2100T via Power Supply 2 without any break of operation.
Effective Alarm Alert for Better Protection
The ICS-2100T comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-2100T provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.
Access Control System – Traditional System Application
Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-2100T Serial Device Server, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-2100T can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet.
Process Control
To monitor, configure and manage the robotic conveyer including other production machines, PLC (Programmable Logical Control) is required to drive the above manufacturing process. The ICS-2100T can be set to the TCP Server mode and connected to the PLC. Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.
Surveillance Motion Control – Pair Connection Mode
Using pair connection mode via the fiber optic patch cord, the ICS-2100T can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient.
Serial Interface
Ethernet Interface
Management
Industrial Case and Installation
Serial Interface | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Serial Ports | 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 |
||||||||||||||||||||||||||||||||||||||||
Serial Standards | RS232 / 4-wire RS422 or RS485 / 2-wire RS485 | ||||||||||||||||||||||||||||||||||||||||
Baud Rate (Data Rate) | 50bps to 921Kbps | ||||||||||||||||||||||||||||||||||||||||
Data Bits | 5, 6, 7, 8 | ||||||||||||||||||||||||||||||||||||||||
Parity Type | 1, 1.5, 2 | ||||||||||||||||||||||||||||||||||||||||
Stop Bit | Odd, Even, None, Space, Mark | ||||||||||||||||||||||||||||||||||||||||
Flow Control | RTS/CTS and DTR/DSR (RS232 only) XON/XOFF |
||||||||||||||||||||||||||||||||||||||||
Signals | RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND 4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND 2-wire RS485: Data A (+), Data B (-), GND |
||||||||||||||||||||||||||||||||||||||||
Pin Assignment |
|
||||||||||||||||||||||||||||||||||||||||
Ethernet Interface | |||||||||||||||||||||||||||||||||||||||||
Ethernet Ports | 1 x RJ45 | ||||||||||||||||||||||||||||||||||||||||
Standard | 10/100BASE-TX | ||||||||||||||||||||||||||||||||||||||||
Distance | 100m | ||||||||||||||||||||||||||||||||||||||||
ESD Protection | 6KV | ||||||||||||||||||||||||||||||||||||||||
Surge Protection | 2KV | ||||||||||||||||||||||||||||||||||||||||
Hardware | |||||||||||||||||||||||||||||||||||||||||
Installation | DIN-rail kit and wall-mount ear | ||||||||||||||||||||||||||||||||||||||||
Enclosure | IP 30 metal | ||||||||||||||||||||||||||||||||||||||||
Dimensions (W x D x H) | 32 x 87.8 x 135 mm | ||||||||||||||||||||||||||||||||||||||||
Weight | 392g | ||||||||||||||||||||||||||||||||||||||||
LED Indicators | System: Power 1, Power 2, Fault, SYS TP Port: Link/Active Serial Port: Tx and Rx |
||||||||||||||||||||||||||||||||||||||||
Power Requirements | 9~48V DC / 24V AC, redundant power with reverse polarity protection | ||||||||||||||||||||||||||||||||||||||||
Power Consumption | Full Loading 9VDC: 0.35A (3.15 watts) 12VDC: 0.28A (3.36 watts) 24VDC: 0.12A (3 watts) 48VDC: 0.08A (3.84 watts) |
||||||||||||||||||||||||||||||||||||||||
Connector | Removable 6-pin terminal block for power input Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2 |
||||||||||||||||||||||||||||||||||||||||
Alarm | Provides one relay output for power failure Alarm relay current carry ability: 1A @ DC 24V |
||||||||||||||||||||||||||||||||||||||||
Reset Button | < 5 sec: System reboot > 5 sec: Factory default |
||||||||||||||||||||||||||||||||||||||||
Management | |||||||||||||||||||||||||||||||||||||||||
Management Interfaces | Web management Telnet Console management Windows-based VCOM Utility management SNMPv1, v2c / SNMP Trap UNI-NMS monitoring PLANET Smart Discovery Utility |
||||||||||||||||||||||||||||||||||||||||
IP Version | IPv4 and IPv6 | ||||||||||||||||||||||||||||||||||||||||
Operation Mode | TCP Server TCP Client UDP Client Virtual COM RFC2217 Telnet Server Pair Connection – Remote (Slave) Pair Connection – Local (Master) Modbus converter server / client |
||||||||||||||||||||||||||||||||||||||||
Virtual COM Utility Platform Supports | Windows-based Only: Windows XP Windows Server 2003 Windows 7 Windows Server 2008 Windows 8 (Must install the latest version of WinPcap) Windows Server 2012 (Must install the latest version of WinPcap) Windows 10 |
||||||||||||||||||||||||||||||||||||||||
Security | Allow max. 4 accessible IP address hosts/ranges | ||||||||||||||||||||||||||||||||||||||||
SNMP MIBs | RFC1213 MIB-II RFC1317 RS232-like MIB |
||||||||||||||||||||||||||||||||||||||||
Standards Conformances | |||||||||||||||||||||||||||||||||||||||||
Regulatory Compliance | FCC Part 15 Class A, CE Certification Class A |
||||||||||||||||||||||||||||||||||||||||
Stability Testing | IEC60068-2-32 (Free fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration) |
||||||||||||||||||||||||||||||||||||||||
Standards | IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX RFC 768 UDP RFC 793 TFTP RFC 791 IP RFC 792 ICMP RFC 854 Telnet RFC 958 NTP RFC 1591 DNS (client only) RFC 1908 SNMPv2c RFC 2068 HTTP RFC 2131 DHCP Client RFC 2732 Format for Literal IPv6 Addresses in URL's RFC 3315 DHCPv6 Client RFC 3513 IPv6 Addressing Architecture RFC 3596 DNSv6 RFC 4443 ICMPv6 EIA/TIA RS232/422/485 |
||||||||||||||||||||||||||||||||||||||||
Regulatory Approval | RoHS | ||||||||||||||||||||||||||||||||||||||||
Environment | |||||||||||||||||||||||||||||||||||||||||
Operating Temperature | -40 ~ 75 degrees C | ||||||||||||||||||||||||||||||||||||||||
Storage Temperature | -40 ~ 85 degrees C | ||||||||||||||||||||||||||||||||||||||||
Humidity | 5 ~ 95% (non-condensing) |
Date | Version | Description | Download |
---|---|---|---|
2020-06-12 | 1.0 | ICS-2100T |
Date | Version | Description | Download |
---|---|---|---|
2020-04-07 | 1.1 | Initial release. |
Date | Version | Description | Download |
---|---|---|---|
2023-04-21 | 1.2 | Modify contents of user manual. | |
2020-07-30 | 1.1 | Initial release. |
Date | Version | Description | Download |
---|---|---|---|
2023-12-26 | 1.0 | EC Declaration. |
Ordering Information | |
---|---|
ICS-2100T |
Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 10/100TX, -40~75 degrees C) |