Flexible Split-core Current Measurement
The PLANET CT Series split-core current transformers are designed for fast and convenient AC current measurement without disconnecting existing conductors during installation. Available with rated current options from 60A to 600A and a standard 333mV AC output, the series provides 0.5% full-scale accuracy and is compatible with PLANET smart power meters featuring a 333mV CT input. Its split-core construction simplifies installation in existing electrical panels, making it suitable for energy monitoring, power management, building automation and electrical equipment applications.
Applying Split-core Current Transformers to Smart Power Meters
The PLANET CT Series split-core current transformers can be connected to PLANET smart power meters with a 333mV CT input, including the SPM-D01-M and SPM-D05/D10 Series. Their split-core design allows the sensor to be installed around an existing conductor without disconnecting the cable, simplifying installation in electrical panels and retrofit projects. With rated current options of 60A, 100A, 200A, 400A and 600A, the series supports current measurement for various electrical loads in energy monitoring, power management and building automation applications.
| Hardware Specifications | |
|---|---|
| Sensor Type | Split-core Current Transformer |
| Primary Rated Current | CT-60A-16: 60A CT-100A-16: 100A CT-200A-24: 200A CT-400A-35: 400A CT-600A-35: 600A |
| Secondary Rated Output | 333mV AC |
| Accuracy | 0.5% F.S. |
| Phase Linear Error | <=30 minutes |
| Operating Voltage | <=720V AC |
| Frequency Range | 50Hz to 1kHz |
| Opening Diameter | CT-60A-16: 16mm CT-100A-16: 16mm CT-200A-24: 24mm CT-400A-35: 35mm CT-600A-35: 35mm |
| Lead Length | 2m |
| Cable | AWM1015, 22AWG (0.34mm2), black-and-white twisted pair |
| Output Lead Wiring | S1 (white): K terminal; S2 (black): L terminal |
| Dimensions (W x D x H) | CT-60A-16: 33.9 x 37.8 x 49.0mm CT-100A-16: 33.9 x 37.8 x 49.0mm CT-200A-24: 40.2 x 53.3 x 69.9mm CT-400A-35: 42.8 x 67.0 x 83.1mm CT-600A-35: 42.8 x 67.0 x 83.1mm |
| Weight | CT-60A-16: 100g CT-100A-16: 100g CT-200A-24: 205g CT-400A-35: 375g CT-600A-35: 375g |
| Case Material | Nylon, Resin 94-V0 |
| Environmental Specifications | |
| Operating Temperature | -15 to 50 degrees C |
| Safety and Regulatory Compliance | |
| Insulation Resistance | 100MOhm at 500V DC |
| Dielectric Strength | 4000V AC for 10 seconds |
| Regulatory Compliance | CE |
| Ordering Information | |
|---|---|
CT-60A-16 |
60A Split-Core Current Transformer with 333mV Output |
CT-100A-16 |
100A Split-Core Current Transformer with 333mV Output |
CT-200A-24 |
200A Split-Core Current Transformer with 333mV Output |
CT-400A-35 |
400A Split-Core Current Transformer with 333mV Output |
CT-600A-35 |
600A Split-Core Current Transformer with 333mV Output |
Split-Core Current Transformer with 333mV Output